26 27 1 8 composite deck slab design.
Concrete on metal deck stc rating.
Slabs can be designed with u l.
Iic 40 cad drawing composite slab of 3 thick concrete steel deck and steel joists with rsic 1 and double layer 5 8 gypsum board ceiling.
Refer to the u l.
Fire rating of one or two hours without applying drywall or spray on fireproofing to the deck.
Working on an existing renovation project in nyc that requires a 1 hr fire rating between occupancies.
1 877 4ad mix1 1 877 423 6491.
These options are not based on the building framing whether steel or concrete but on the stc rating desired.
24 25 1 7 steel deck at concrete form.
Fire resistance directory for the necessary construction details.
Concrete topping an stc rat ing of 51 can be achieved.
Slabs use less concrete than a traditional solid slab reducing total concrete volume up to 30 percent.
22 23 1 6 web crippling.
Stc rating of 55.
2 3 4 unrestrained beam rating.
Stc iic ratings for fc 214 floor covering stc iic test number carpet pad 48 54 nrc 1059 1060 vinyl 47 35 nrc 1063 1064 lightweight concrete carpet pad 56 72 nrc 1053 1054 lightweight concrete and vinyl 56 48 nrc 1051 1052 gypcrete carpet pad 52 63 nrc 1076 1077 gypcrete 53 43 nrc 1085 1086 stc iic ratings for ul l528.
Additionally for an 8 in.
1 5 steel deck section properties.
Concrete thickness is thickness of slab above deck in.
Sound transmission class stc provides an estimate of the acoustic performance of a wall in certain common airborne sound insulation applications the stc of a wall is determined by comparing sound transmission loss stl values at various frequencies to a standard contour stl is the decrease or attenuation in sound energy in db.
There is an existing 5 1 2 concrete slab between the floors requiring the separation can t seem to find in code whether this might be an acceptable separation as most of the data i m seeing seems to show we should be above 1 hr with that thickness of concrete.
28 30 1 9 non composite deck slab design.
Restrained assembly rating type of protection concrete thickness type 1 classified deck type u l.
With no additional sound isolation system a 6 inch concrete slab has an stc of 53 and an iic of 27 so treatment of at least the impact noise is necessary to meet code.
31 1 10 penetrations and openings.
Determining sound transmission class stc for concrete masonry.
With option 10 a concrete floor slab on metal deck 3 in.
Independent sound transmission stc tests prove that ultrabond slabs outperform other floor systems.
Deck finish shall be galvanized 2.
Riverbank acoustical laboratory ral test number tl01 220.